產(chǎn)品展示 / products 您的位置:網(wǎng)站首頁(yè) > 產(chǎn)品展示 > > 美國(guó)omega熱電偶溫度變送器 > 美國(guó)omega TX94A-3-SS-M12F-2變送器

美國(guó)omega TX94A-3-SS-M12F-2變送器

簡(jiǎn)要描述:美國(guó)omega TX94A-3-SS-M12F-2變送器, 一手貨源,優(yōu)勢(shì)批發(fā),精度高,是優(yōu)質(zhì)的變送器。

  • 產(chǎn)品型號(hào):
  • 廠商性質(zhì):代理商
  • 更新時(shí)間:2024-04-09
  • 訪  問(wèn)  量:1754
詳情介紹

 美國(guó)omega TX94A-3-SS-M12F-2變送器

RTD溫度變送器 - 316不銹鋼構(gòu)造
TX94A-SS Series Temperature Transmitter
RTD溫度變送器 - 316不銹鋼構(gòu)造
TX94A-SS Series Temperature Transmitter:RTD溫度變送器 - 316不銹鋼構(gòu)造
TX94A-1-SS-M12F-1
Ideal for Wash-down, Outdoor, Sanitary or Marine Environments
Compact Design Attaches Directly to Most 3-Wire and 4-Wire, Pt100, 0.00385 Curve Sanitary Probes and Sensors with M12 Style Connectors
True 2-Wire Operation, Loop Powered 4 to 20 mA Output
Sealed Signal Conditioner Built Into NEMA 4X (IP67) 316 Stainless Steel Housing
±0.1% FS Accuracy, High Repeatability, and Stability
Both Zero and Span Adjustments for Field Calibration
Provides “Upscale" Break Detection and Compensates for Long Lead Wires
Loop Powered! The OMEGA? 2-wire TX94A-SS Series temperature transmitters are high-performance, industrial transmitters designed for

direct connection to most CIP (clean-inplace) Sanitary Pt100 probes and sensors that incorporate a M12 style connection. All models feature a miniature signal

 conditioner built into a sealed stainless steel connector housing. The signal conditioner converts the resistive change of a 100 Ω, 0.00385 RTD probe or sensor into an industry-standard 2-wire, 4 to 20 mA analog output across a dedicated temperature range. Output connection is also a standard M12 connector.
M12 RTD SENSOR WIRING
Wiring option #1 Wiring option #2
The TX94A-SS transmitter is provided with two RTD wiring configurations as shown. The wiring style is identified at the end of the model number by either a

"-1" or "-2". If used with an Omega PR-21 sensor, then the "-1" or "-2" ion should match the final charecters following the "-M12" in the sensor model number

(ie: PR-21A-3-100-A-1/4-0600-M12-1). When using the transmitter with an Omega PR-22 style RTD, then please  the -2 wiring configuration.
Examples:
For use with a PR-21A-3-100-A-1/4-0600-M12-1, use an TX94A-2-SS-M12F-1 Transmitter (Range is -18 to 93°C).
For use with a PR-22-3-100-A-M6-250-M12 sensor, use an TX94A-2-SS-M12F-2 Transmitter (Range is -18 to 93°C).
SPECIFICATIONS
Supply Voltage: 8 to 35 Vdc; (24 Vdc recommended)
Max Load: Rmax (Ω) = (Vsupply - 8V)/0.02 A
Output: Linearized 4 to 20 mA
Accuracy: ±0.1% FS (includes effects of linearity, hysteresis and repeatability)
Frequency Response: 3 dB @ 3Hz
Range:
1: -40 to 49°C (-40 to 120°F)
2: -18 to 93°C (0 to 200°F)
3: -18 to 149°C (0 to 300°F)
4: -18 to 260°C (0 to 500°F)
Input: 3-wire, Pt100 (α = 0.00385), 4-wire RTD compatible Probe/Sensor Input
Connection:
TX94A-SS-M12M: M12 style, 4-pin male
TX94A-SS-M12F: M12 style, 4-pin female
Transmitter Operating Temp: -40 to 85°C (-40 to 185°F)
Output Connection (All Models): M12 style (order cable from table below)
Housing: 316 stainless steel, polished mirror finish
Approvals: CE marked
Dimensions: 51 H x 38 mm D (2.0 x 1.50")

產(chǎn)品型號(hào)/產(chǎn)品描述


TX94A-1-SS-M12M-1  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -40 to 49°C (-40 to 120°F)
TX94A-1-SS-M12M-2  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -40 to 49°C (-40 to 120°F)
TX94A-2-SS-M12M-1  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 93°C (0 to 200°F)
TX94A-2-SS-M12M-2  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 93°C (0 to 200°F)
TX94A-3-SS-M12M-1  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 149°C (0 to 300°F)
TX94A-3-SS-M12M-2  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 149°C (0 to 300°F)
TX94A-4-SS-M12M-1  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 260°C (0 to 500°F)
TX94A-4-SS-M12M-2  4 to 20 mA transmitter with M12, male 4-pin RTD connection, -18 to 260°C (0 to 500°F)
TX94A-1-SS-M12F-1  4 to 20 mA transmitter with M12, female 4-pin RTD connection, -40 to 49°C (-40 to 120°F)
TX94A-1-SS-M12F-2  4 to 20 mA transmitter with M12, female 4-pin RTD connection, -40 to 49°C (-40 to 120°F)
TX94A-2-SS-M12F-1  4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 93°C (0 to 200°F)
TX94A-2-SS-M12F-2  4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 93°C (0 to 200°F)
TX94A-3-SS-M12F-1  4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 149°C (0 to 300°F)
TX94A-3-SS-M12F-2 4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 149°C (0 to 300°F)
TX94A-4-SS-M12F-1 4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 260°C (0 to 500°F)
TX94A-4-SS-M12F-2 4 to 20 mA transmitter with M12, female 4-pin RTD connection, -18 to 260°C (0 to 500°F)
Accessories
PSR-24S  Regulated power supply, 24 Vdc, 400 mA, screw terminal
PSR-24L  Regulated power supply, 24 Vdc, 400 mA, UL, stripped leads
PSR-24L-230  Regulated power supply, 24 Vdc, 400 mA, stripped leads, 230 Vac input, CE
CAL-3  NIST traceable calibration with data
Output Cables
M12C-PUR-4-S-F-5  Cable, M12, 4-pin female, polyurethane jacket, 5 m (16.4') long
M12C-PVC-4-S-F-5  Cable, M12, 4-pin female, PVC jacket, 5 m (16.4') long

 美國(guó)omega TX94A-3-SS-M12F-2變送器

相關(guān)產(chǎn)品:

美國(guó)omega SPRTX-SS1-M12-1變送器



留言詢價(jià)

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
技術(shù)支持:化工儀器網(wǎng)   sitemap.xml   管理登陸
© 2024 版權(quán)所有:深圳市鑫博恒業(yè)科技有限公司( m.hzaichao.com)   備案號(hào):粵ICP備09037369號(hào)